Datasheet
Clogging
For single shift use respirators (NR), the clogging test is
optional. For re-usable respirators (R) this test is mandatory.
The respirators are loaded with very high amount of Dolomite
dust which will tend to clog the lter. After loading with the
required amount of dust, the breathing resistance of the
respirators shall not exceed the following limits:
Maximum Breathing Resistance
EN 149:2001
+A1:2009
Classication
Inhalation at 95l/min Inhalation at 160l/
min
FFP1
4.0 mbar
(valved respirator)
3.0 mbar
(unvalved respirator)
3.0 mbar
(valved respirator)
FFP2
5.0 mbar
(valved respirator)
4.0 mbar
(unvalved respirator)
3.0 mbar
(valved respirator)
FFP3
7.0 mbar
(valved respirator)
5.0 mbar
(unvalved respirator)
3.0 mbar
(valved respirator)
Flammability
Tested respirators are mounted on a metallic head which
rotates with a linear speed of 60mm/s. The respirators are
passed within 20mm of the tip of an 800oC (±500C) propane
burner ame. The respirator shall not burn or continue to burn
within 5 seconds of removal from the ame.
Components and Materials
The following materials are used in the production of the
3M™ Aura™ Particulate Respirators 9300+Series:
Component Material
Straps Polyisoprene
Staples Steel
Nose Foam Polyurethene
Nose clip Aluminium
Filter Polypropylene
Valve Polypropylene
Exhalation Valve Polyisoprene
This product does not contain components made from
natural rubber latex.
Product Range
Product Typical weight
3M ™ Aura
™ Particulate
respirator 9310+
10g
3M ™ Aura
™ Particulate
respirator 9312+
15g
3M ™ Aura
™ Particulate
respirator 9320+
10g
3M ™ Aura
™ Particulate
respirator 9322+
15g
3M ™ Aura
™ Particulate
respirator 9330+
10g
3M ™ Aura
™ Particulate
respirator 9332+
15g
Storage and Transportation
3M™ Aura™ Particulate Respirators 9300+ Series have a
shelf life of 5 years from date of manufacture. End of shelf life
is marked on the product packaging and upon the product.
Before initial use, always check that the product is within the
stated shelf life (use by date).
Product should be stored in clean, dry conditions within
the temperature range: – 20°C to + 25°C with a maximum
relative humidity of <80%. When storing or transporting the
respirator, remove bend in noseclip, align top and bottom
panels together before pushing the top panel at. Store
respirator in original packaging provided.
3M™ Aura™ Particulate Respirators 9300+ Series