7.15 Controls, Valves, Switch Locations
1. Electrical/Pneumatic “On/O ”
Switch
The switch box houses an under
voltage motor protection release
circuit breaker that supplies AC
power to the Electrical Control Box
The Circuit Breaker is preset and
requires no further maintenance.
If circuit is overloaded and trips,
unplug machine from power source:
a) Determine and correct cause of
overload.
b) Reconnect machine to power
source.
c) Turn “On/O ” and Push Button
Switches “On”.
2. Main Air “On/O ” Valve/Pressure
Regulator/Filter/Exhaust Valve –
Figure 7-15
This set of pneumatic components
controls, regulates and lters plant
air supply to the two separate
control circuits of the case sealer.
“On/O ” Valve – “On” turn to “SUP”
– “O ” turn to “EXH”.
Note – Turning air supply “O ”automa-
tically bleeds air pressure from the
case sealer air circuit (continued)
Refer to Figure 7-14 below to acquaint
yourself with the various components and
controls of the case sealer. Also see com-
ponent locations in Section 3 and Manual 2
and Manual 3 for taping head components.
Important: Always turn the air “O ” when
machine is not in use, when servicing
the machine, or when connecting or
disconnecting air supply line.
Note: See 7.15 Control Function Explanations
9
12
8
2
Mechanical Latch,
Upper Drive Assembly
Main Air Pressure
Gauge
Push Button Station
"Start/Stop"
Main Air On/O Valve/
Pressure Regulator/
Filter/Exhaust Valve
Electric/Pneumatic
"On/O " Switch
Electrical Control Box
Air Pressure Regulator,
Centering Guide Force
Proximity Sensor -
Box Centering
Guides
Upper Drive
Raising Actuator
(with Proximity Sensor)
Emergency
Stop Switch
Upper Drive
Pressure Gauge
Figure 7-13 Controls, Valves and Switches
Figure 7-15
Filter
Down
to Lock
Solenoid
Exhaust
Valve
Up to
Adjust
Air Supply
Connector
Air On/O
Valve
Regulator
1
12
1
11
7
Air Pressure Regulator, Upper Drive
Assembly Pneumatic Force
6
10
5
4
3