Datasheet

3M
Reusable Half Masks 6500QL Series
Particulate Filters
Filter Standard Class Hazard
5911
5925(06925)
5935
EN 143:2000 /
A1:2006
P1 R
P2 R
P3 R
Particulates (fine dusts and mists)
Combine 5911/5925/5935 with 6000 series Gas/
Vapour filters with the 501 filter retainer
501 Filter Retainer for 5911, 5925 and 5935
2125
2135
EN 143:2000 /
A1:2006
P2 R
P3 R
Particulates (fine dusts and mists)
2128
2138
EN 143:2000 /
A1:2006
P2 R
P3 R
Particulates, ozone and nuisance levels* of organic
vapours and acid gases
6035
EN 143:2000 /
A1:2006
P3 R Particulates (fine dusts and mists)
6038
EN 143:2000 /
A1:2006
P3 R
Particulates, hydrogen fluoride up to 30ppm,
nuisance levels* of organic vapours and acid gases
Standards and approvals
The 3M™ Reusable Half Masks 6500QL Series meets the
performance requirements of the European Standard EN 140
for Half Masks. The Certificate and Declaration of Conformity
are available from the following website:
www.3M.com/Respiratory/certs
Intended use
When the 3M™ Reusable Half Masks 6500QL Series is fitted
with Gas andVapour Filters: 6000 Series gas and vapour
filters may be used in concentrations of gases or vapours
(types specified by 3M) up to 10 x the Workplace Exposure
Limit (WEL) or 1000ppm (5000ppm for 6055) whichever
value is lower. 6075 and 6092 also offer protection against
concentrations of formaldehyde (10ppm only). 6000
Series gas and vapour filters should not be used to protect
the wearer against a gas or vapour that has poor warning
properties (smell or taste).
When the 3M™ Reusable Half Masks 6500QL Series is
fitted with Particulate Filters: 5911 filters may be used in
concentrations of particulates up to 4 x WEL. 5925, 2125 or
2128 filters may be used in concentrations of particulates up
to 10 x WEL. 3M™ Particulate Filters 2138, 2135, 5935, 6035
or 6038 may be used in concentrations of particulates up
to 20 x WEL. 3M™ Particulate Filters 2128 and 2138 may be
used to protect against ozone up to 10 x WEL and offers relief
from acid gases and organic vapours at levels below the WEL.
3M™ Particulate Filter 6038 offers protection against up to
30ppm Hydrogen Fluoride gas and offers relief from, acid
gases and organic vapours at levels below the WEL.
Use limitations
Before use, check the expiration date.
For other use limitations please refer to the User Information
supplied with the products. These respirators do not supply
oxygen. Do not use in oxygen deficient areas.**
Do not use for respiratory protection against atmospheric
contaminants that have poor warning properties or are
unknown or immediately dangerous to life and health (IDLH)
or against contaminants, which generate high heats of
reaction with chemical filters. (The 3M
S-200 Supplied-Air
Respirator System can be used against contaminants with
poor warning properties, subject to other use limitations).
Donot misuse, alter, modify or repair this product. Do not use
with beards or other facial hair that prevent direct contact
between the face and the edge of the respirator. Do not use
with unknown concentrations of contaminants.
Leave the work area immediately and check the integrity
ofthe respirator and replace face mask if: Damage has
occurred or is apparent. Breathing becomes difficult or
increased breathing resistance occurs. Dizziness or other
distress occurs. You taste or smell the contaminant or an
irritation occurs.
** 3M definition minimum 19.5% by volume oxygen
*Nuisance levels are levels below the relevant Workplace Exposure Standard.