Datasheet

3M
Cool Flow
Fan 1040 Series
for use with the 3M
4000+ Series
Reusable Half Face Masks
Product description
3M
Cool Flow
Fan 1040 Series is designed to be used with
the 3M
4000+ Series Reusable Half Face Masks which are
a range of ready-to-use, maintenance-free half face masks.
It is designed to reduce heat and moisture build up inside the
mask to aid wearer comfort. It includes a rechargeable battery
and can be recharged with the included USB charger.
Key features
Ŕ Rechargeable
Ŕ 3 levels of operation, to help the wearers choose
alevelthatis appropriate for their needs
Ŕ Single button operation, easy to use
Product range and intended use
1. See 3M
4000 Series Maintenance Free Reusable
Respirator user instructions for list of use limitations
fortherespirator.
2. Never modify or alter this product.
3. Only use chargers supplied with the unit.
(Egston BI12T-050100-BdV)/(Egston BI12T-050100-BdB)/
CUI SWI5-5-B-I38-Cx)/(CUI SWI5-5-E-I38-Cx).
4. Do not use standard version 3M
Cool Flow
Fan
inpotentially explosive environments.
5. Do not switch on 3M
Cool Flow
Fan before you have
donned the respirator with 3M
Cool Flow
Fan attached.
6. When the 3M
Cool Flow
Fan is used with 3M
4000+
Series, the respirator continues to exceed the gas capacity
requirements of EN 405. When tested at the flows stated
in EN 405, however, the service life of the respirator with
organic vapour filters may reduce by up to 20%. The
service life of the respirator with inorganic vapour, acid
gas and ammonia filter may reduce by up to 33%. Please
take this into account when considering your change
outschedule.
Technical datasheet
7. The 3M
Cool Flow
should not be used in the
followingconditions:
a. In atmospheres containing less than 19.5% oxygen
b. Confined spaces (lack of ventilation)
c. When the risk is Immediately Dangerous for Life
orHealth(IDLH)
d. Where the contaminant concentration is above the
protection limit defined for 4000+ user instructions
For full use limitations please refer to the product
userinstructions.
Technical specifications:
Standards and approvals
3M
1040 standard version, is approved as an accessory
tothe 3M
Respirator, 4000+ Series. They also comply
withthe European EMC Directive 2014/30/EU.
Battery charge time
4 hours
Charging temperature
+15°C to +40°C

Summary of content (2 pages)