Datasheet
3M
™
Cool Flow
™
Fan 1040 Series
for use with the 3M
™
4000+ Series
Reusable Half Face Masks
Product description
3M
™
Cool Flow
™
Fan 1040 Series is designed to be used with
the 3M
™
4000+ Series Reusable Half Face Masks which are
a range of ready-to-use, maintenance-free half face masks.
It is designed to reduce heat and moisture build up inside the
mask to aid wearer comfort. It includes a rechargeable battery
and can be recharged with the included USB charger.
Key features
Ŕ Rechargeable
Ŕ 3 levels of operation, to help the wearers choose
alevelthatis appropriate for their needs
Ŕ Single button operation, easy to use
Product range and intended use
1. See 3M
™
4000 Series Maintenance Free Reusable
Respirator user instructions for list of use limitations
fortherespirator.
2. Never modify or alter this product.
3. Only use chargers supplied with the unit.
(Egston BI12T-050100-BdV)/(Egston BI12T-050100-BdB)/
CUI SWI5-5-B-I38-Cx)/(CUI SWI5-5-E-I38-Cx).
4. Do not use standard version 3M
™
Cool Flow
™
Fan
inpotentially explosive environments.
5. Do not switch on 3M
™
Cool Flow
™
Fan before you have
donned the respirator with 3M
™
Cool Flow
™
Fan attached.
6. When the 3M
™
Cool Flow
™
Fan is used with 3M
™
4000+
Series, the respirator continues to exceed the gas capacity
requirements of EN 405. When tested at the flows stated
in EN 405, however, the service life of the respirator with
organic vapour filters may reduce by up to 20%. The
service life of the respirator with inorganic vapour, acid
gas and ammonia filter may reduce by up to 33%. Please
take this into account when considering your change
outschedule.
Technical datasheet
7. The 3M
™
Cool Flow
™
should not be used in the
followingconditions:
a. In atmospheres containing less than 19.5% oxygen
b. Confined spaces (lack of ventilation)
c. When the risk is Immediately Dangerous for Life
orHealth(IDLH)
d. Where the contaminant concentration is above the
protection limit defined for 4000+ user instructions
For full use limitations please refer to the product
userinstructions.
Technical specifications:
Standards and approvals
3M
™
1040 standard version, is approved as an accessory
tothe 3M
™
Respirator, 4000+ Series. They also comply
withthe European EMC Directive 2014/30/EU.
Battery charge time
4 hours
Charging temperature