Overview of Primary Product
SECTION 5: SPECIFICATION AND OPERATING DATA
5-1
ITEM
CBF100 CBF150 CBF200 / CBF200 CJ-L
Filter Media Volume, cu. ft. (cu. mtr.) (Note 1):
Gravel Underbed, lbs. (kg)
Operating Flow Rate, gpm (lpm) (Note 2):
Backwash Flow Rate, gpm (lpm) Note 3
Service Pipe Size, in. (cm) (Note 4)
Filter Tank Diameter x Height, in. (cm)
Minimum Space Required, in. (cm):
Width
Depth (w/Bypass)
Height
Approximate Shipping Weight, lbs. (kg)
1.0 (0.03)
13 (5.9)
3 (11.4)
5.3 (20.1)
1 (2.5)
10 x 44
(26 x 112)
10 (26)
16 (41)
53 (135)
53 (24)
1.5 (0.04)
13 (5.9)
3 (11.4)
5.3 (20)
1 (2.5)
10 x 54
(26 x 137)
10 (26)
16 (41)
63 (160)
59 (26.7)
2.0 (0.06)
18 (8.2)
4 (15.1)
7.5 (28.4)
1 (2.5)
12 x 54
(30 x 137)
12 (31)
16 (41)
63 (160)
62 (28.1)
Maximum Operating Temperature 110°F (43.3°C); Electrical requirements 110V/60Hz; Operating Pressure 20 -100 psi (138-689 kPa). Specifi cations
subject to change without notice.
IMPORTANT NOTES
IMPORTANT NOTES
1) Replenishment of pH adjusting component of media may be required periodically, the frequency of which is dependent on raw water pH, manga-
nese concentration and water consumption rate. Consult our Customer Service Department at 1-866-990-9785 for more information.
2) For satisfactory performance, indicated durations should not be exceeded. Flow rates specifi ed are adequate for normal residential applications.
Do not use listed fl ow rates if treated water is to supply a geothermal heat pump, etc. (contact Customer Service Department at 1-866-990-9785
before selecting equipment).
3) For your CBF Series Residential Backwash Filtration System to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit
at rate specifi ed.