User's Guide
Appendix B : Connectivity via COM Port
3D-P recommends the use of a console application such as PuTTY (free) or SecureCRT (paid)
to connect to the console port on the Osprey Intelligent Endpoint. The settings for a console
connection are:
Setting
Value
Baud rate
38400
Data bits
8
Parity
none
Stop bits
1
RTS/CTS
off
XON/XOFF
off
Appendix C : Connectivity via Recovery IP
All Ospreys offer a Recovery IP (192.168.77.77/24), available as a secondary IP address on
eif0 (also labelled eth0), the first Ethernet interface.
To connect, set the ethernet card in your laptop/desktop to use the following details:
Setting
Value
IP Address:
192.168.77.78
Subnet
255.255.255.0
TOP TIP:
Any IP address can be used in the that subnet, with the obvious exceptions of:
192.168.77.0, 192.168.77.77, 192.168.77.255
A default gateway is not required for this connection.
Connecting using the Recovery IP gives web-based GUI access to an onboard web interface.
Open a browser (Firefox, Chrome, Safari supported) and browse to:
http://192.168.77.77
For more information on device software features & login information refer to the Ties system
user guide