User's Manual

Our duty is ensure your safety, so you can rely on an excellent device
3) 3 Speed – Pushbutton A and B will share their 2
nd
step relay to apply as the 2
nd
/3
rd
relay , i.e. A2
relay for 2nd step relay, B2 is for 3rd step replay.
The above pushbuttons can also be set independently for the following functions :
1) Normal – Normal function, press button and RELAY is on, release button is off.
2) Toggle – Press Firstly is ON, press again is OFF, please note the function is only for 1
st
speed ,
2
nd
speed is no such function.
3) Special – For some special application, such as for hoist 1
st
step and 2
nd
step is operated by two
different motor, the special function setting can be set to SWITCH the first motor and second motor.
And 1
st
step and 2
nd
step can set “ SWITCH DELAY TIME “ from 0.1~5 sec.
Or you may set two Trolleys ( Trolley A/B ) be operated by turns.
< using Toggle & Interlock setting >. ( see fig.4 )
4) Main Relay “ linked with “ – Main relay can be set to link with movement relay, this function
normally to apply on hydraulic system for oil pump use. ( see fig. 5 )
NOTE !!
Every set of motion ( A/B, C/D, E/F, G/H, I/J, K/L ) is interlocked to each other as ex-factory
Setting. That means to press up/down simultaneously , there is no function output for
security reason.
Function Kit ( fig. 3 )
( fig. 4 )