User's Manual

Our duty is ensure your safety, so you can rely on an excellent device
APOLLO C2-8PB Installation Wiring Diagram
K14 CPU
K13 Main
K1 A
K2 B
K3 C
K4 D
K5 E
K6 F
K7 G
K8 H
ST
1 step in
ST
1 step in
ST
1 step in
ST
1 step in
ST
1 step in
ST
1 step in
ST
1 step in
ST
1 step in
ND
L1 2 step in A
ND
L2 2 step in B
ND
L3 2 step in C
ND
L4 2 step in D
ND
L5 2 step in E
ND
L6 2 step in F
ND
L7 2 step in G
ND
L8 2 step in H
F1 0.5A Power Fuse
F2 5A Main Fuse
C2-8PB
ST
1 step in A
ST
1 step in B
ST
1 step in C
ST
1 step in D
ST
1 step in E
ST
1 step in F
ST
1 step in G
ST
1 step in H
Common
EMS-Stop
APOLLO C2-8PB
ND
2 step in A
ND
2 step in B
ND
2 step in C
ND
2 step in D
ND
2 step in E
ND
2 step in F
ND
2 step in G
ND
2 step in H
Common
1
2
3
4
5
6
7
8
11
12
13
14
15
16
17
21
18
22
23
24
25
Power
87654321
CPU
ON
F1
K14
K1
K2
COMMON
K3
K4
COMMON
JP11
K5
K6
COMMON
K8
COMMON
K13
COMMON
FUSE 5A
K7
COMMON
POWER
POWER
FUSE 0.5A
K14
CPU
JP12
JP13
JP14
JP5
F2
K3
K4
K5
K6
K7
K8
K2
K1
K13
L1
L2
L3
L4
L5
L6
L7
L8
L1
COMMON
JP21
L2
L3
COMMON
Jp22
L4
L5
COMMON
Jp23
L6
L7
COMMON
Jp24
L8
AC-110V
AC-220V
AC-380V
AC-415V
1
2
21
3
4
21
5
6
21
7
8
21
21
21
18
17
21
16
15
21
14
13
21
12
11
25
24
23
22
2nd step relay board
Connect w/LED
Connect w/HF
decoder & relay board (REV:3.21)
ID codes
HF board
HF board
Button-legend
(custom-made on demand)
AC-110V
AC-220V
AC-380V
AC-415V
FUSE 0.5A