Manual

Table of Parameters
3.2
32
Tone settings
Dial tone Double frequency tone[Hz] Function No.: -
Parameter can be set for all three types of tone (Dial tone, Busy
tone,Ringbacktone). This parameter is intended for switching between single
tone and double tone setting. When the parameter is set, the second frequency

frequency is automatically set to the same value, which results in single tone
          
the phone line programming is used for frequency change, both tones must be
set (for single frequency to the same value).
Setting options: YES/NO
Default setting: NO
Dial tone frequency 1[Hz] Function No.: 120
Setting of frequency 1 of dial tone. This tone is generated after Off-Hook in case
is ready to accept dialing.
Setting options: 1-3400 Hz
Setting step: 1 HzD
efault setting: 425 Hz
Dial tone frequency 2[Hz] Function No.: 121
Setting of frequency 2 of dial tone.
Setting options: 1-3400 Hz
Setting step: 1 Hz
Default setting: 425 Hz
Dial tone - cadence Function No.: 122
Dial tone cadence setting.
Setting options: Continuous ( 0) -2N® SmartGate generate continuous
dial tone
Morse A (1) -2N® SmartGate generate dial tone with
330/330/660/660 ms timing
Default setting: Continuous
Busy tone frequency 1[Hz] Function No.: 123
Setting of frequency 1 of busy tone.
Setting options: 1-3400 Hz
Setting step: 1 Hz
Default setting: 425 Hz
Busy tone frequency 2[Hz] Function No.: 124
Setting of frequency 2 of busy tone.
Setting options: 1-3400 Hz
Setting step: 1 Hz
Default setting: 425 Hz