User Manual
34
2.5 Extending Module Connection
2N
Helios features an easy installation of extending button modules. Extending
modules are connected using a single cable (included in every extender delivery) in a
chain pattern (every additional unit is connected with the previous one). Each
extending module has two connectors an input connector (for connection towards
the 2N
Helios basic unit) and an output connector (for connection of another, more
remote unit). Be sure to maintain the correct orientation of the units and avoid
connector mismatch to ensure a proper function of the device!
Module Cable Interconnection
The cable is included in every extending module delivery. Both its ends are
the same. Configuration is 1:1. Connectors cannot be shifted or inserted
conversely because they are equipped with a so-called key.
The basic unit is always on the left. Extenders are chain-connected, i.e.
each is linked with its neighbour.
The cable cannot be driven through the box interconnecting holes until the
boxes have been connected (see subsection 2.3 Mounting Mechanical
Installation).
Basic unit
Extender unit
Removed upper part of
(open)
(bottom part)
extender module
Fig.: 8-Button Extender Module Connection to Basic Unit
Connector for next extender module
connection