Manual

762N TELEKOMUNIKACE a.s., www.2n.cz
®
Users
This section helps you manage the SMS users. Select a communication protocol for
user adding (SMTP/POP3 or SMPP).
Add user
User group – assign the user to a User group.
User full name – define the system user name.
Replace dial for outgoing SMS – define the number (CPN) to which
the user's outgoing SMS messages shall be sent.
Access type select the communication protocol for SMS
processing:
Email (SMTP/POP3) use SMTP for SMS sending and POP3
for SMS receiving.
SMPP (SMSC) set the GSM gateway into the 'SMS centre'
mode.
SMPP (ESME) set the GSM gateway into the 'ESME -
External Short Messaging Entity' mode.
Login name (without domain) define the login name for the
client Email.
System ID – SMSC user .ID
Password – SMSC/SMTP user password.
System ID (for authentication on remote side) – ESME user ID.
Password (for authentication on remote side) – ESME user ID.
TCP type – set the TCP parameter into the client/server mode.
Server address set the server IP address and TCP server
transport port.
Message direction of Esme – set the ESME user details:
Transceiver – ESME works as a transmistter/receiver.
Transmitter – ESME works as a transmitter.
Receiver – ESME works as a receiver.
Address range set this parameter if required so by SMSC for SMS
receiving.
Delivery status required set the SMS sending request for
Caution
The count of user accounts is file-licensed. Refer to Management /
for the current GSM gateway licence details.Licence key