Manual
Table of Parameters
3.2
38
Reception volume Function No.: 191
See FXS interface parameters.
„BabyCall“ – Automatic call
BabyCall number Function No.: 280
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter defines a
number to be dialed for the automatic call function. If this item is blank, the
function is disabled. If only character ‘#’ is included, after BabyCall timeout
elapsed the interfaces FXO and FXS are connected and dialing to PSTN over FXO
interface is possible.
Setting options: 0-20 characters (0-9,*,#,+)
Default setting: blank
BabyCall timeout [s] Function No.: 281
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter defines
time between line Off-Hook and automatic call beginning (if enabled). During
this timeout 2N® SmartGate UMTS waits for dialing that cancels the automatic
call. You can make standard call if the BabyCall function is enabled.
Setting options: 0-255 s
Setting step: 1 s
Default setting: 0 s
Mobility extension FLASH
Mobility Extension FLASH DTMF code Function No.: 240
Fill in DTMF code to enable GSM FLASH function. If 2N® SmartGate UMTS
receive DTMF dialing corresponding to filled code during UMTS/GSM - FXO call, it
generates FLASH to FXO interface.
Setting options: 0-4 characters (0-9,*,#)
Default setting: blank
FLASH length [ms] Function No.: 241
Time of current loop interruption (line On-Hook) during FLASH.
Setting options: 100-1500 ms
Step: 100 ms
Default setting: 100 ms
FXS routing table parameters
All parameters related to the dialed number and call routing are arranged in three
routing tables. Each table pertains to one interface: FXS, FXO and GSM(UMTS).
According to the prefix of dialed number on FXS interface you can: