Manual

Table of Parameters
3.2
35
Telephone interface FXO parameters
Dialing parameters
Number of rings before Off-Hook Function No.: 200
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter sets the
count of rings before Off-Hook.
Setting options: 1-255
Step: 1
Default setting: 1
Timeout for dialing end recognize [s] Function No.: 201
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter defines
timeout during which 2N® SmartGate UMTS waits for further digits to be dialed.
It starts to establish connection when this timeout passes.
Setting options: 1-255 s
Setting step: 1 s
Default setting: 5 s
Time for dialing start Function No.: 202
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter defines
timeout for first dialing digit. After timeout 2N® SmartGate UMTS hangs up the
line.
Setting options: 1-255 s
Step: 1 s
Default setting: 15 s
Beep after dialing end Function No.: 203
If 2N® SmartGate UMTS is programmed as FXO gateway, parameter enables a
beep to signal the end of dialing (beginning of outgoing call establishing).
Setting options: YES(1)/NO(0)
Default setting: YES
Type of transmitted dialing Function No.: 204
Set type of dialing for automatic dial-in from UMTS/GSM and for dialing during
outgoing call from FXS interface.
Setting options: DTMF (0)-2N® SmartGate UMTS transmits tone dialing-
for future use
Default setting: DTMF
Minimal On-Hook [ms] Function No.: 205
Parameter defines minimal time of line On-Hook between calls. Set the
parameter longer then duration of FLASH on your PBX.
Setting options: 100-25500 ms
Step: 100 ms
Default setting: 1500 ms