User Manual, v1.00 Instruction Manual

24
None -EasyGate doesn't send tariff pulse as signaling of call
start/end.
Call end -EasyGate sends tariff pulse when call ends.
Call start -EasyGate sends tariff pulse when call starts.
Call start and end -EasyGate sends tariff pulse when call starts and
ends too.
Default setting: None
Tariff pulse frequency Function No.: -
Tariff pulse frequency setting.
Setting options:
16 kHz -EasyGate transmits 16 kHz tariff pulses
12 kHz -EasyGate transmits 12 kHz tariff pulses
Default setting: 16 kHz
8.3.1.3 Tone settings
Dial tone Double frequency tone[Hz] Function No.: -
Set for double frequency tones
Setting options: YES/NO
Default setting: NO
Dial tone frequency [Hz] Function No.: -
Setting of frequency/frequencies of dial tone.
Setting options: 5-1275 Hz
Setting step: 5 Hz
Default setting: 425 Hz
Dial tone - cadence Function No.: -
This tone is generated after Off-Hook in case EasyGate is ready to accept
dialing.
Setting options:
Continuous -EasyGate generate continuous dial tone
Morse A -EasyGate generate dial tone with 320/320/640/640 ms
cadence
Default setting: Continuous
Busy tone Double frequency tone[Hz] Function No.: -
Set for double frequency tones
Setting options: YES/NO
Default setting: NO
Busy tone frequency [Hz] Function No.: -
Setting of frequency/frequencies of busy tone.
Setting options: 5-1275 Hz
Setting step: 5 Hz