Specification Sheet
Table Of Contents
10Gtek Transceivers Co.,Ltd
Driving Your Next Generation Networks www.10gtek.com
E-mail:info@10gtek.com Tel: +86 755 2998 8100 Fax: +86 755 6162 4140
7
Timing Electrical Interface
Item
Parameter
Symbol
Min
Max
Units
Conditions
1
Time to initialize
t_init
2000
ms
Time from power on, hot plug or
reset until the module is fully
functional.
2
ResetAssert
Time
t_reset
2000
ms
Time from rising edge on the
ResetL pin until the modules is fully
functional
3
IntL Assert Time
ton_IntL
200
ms
From occurrence of fault to
assertion of IntL
4
IntL Negate Time
toff_IntL
500
us
Time t_reset must be held low to
reset IntL.
5
LPMode Assert
Time
ton_LPMode
100
us
Time for assertion of LPMod
Untilmodule power
consumption reached
power level 1.
6
LPMode Negate
Time
toff_LPMode
100
us
Time for deasertion of LPMode
Until module is fully functional