Specification Sheet
Table Of Contents
10Gtek Transceivers Co.,Ltd
Driving Your Next Generation Networks www.10gtek.com
E-mail:info@10gtek.com Tel: +86 755 2998 8100 Fax: +86 755 6162 4140
5
Notes:
1.The module signal ground pins, VeeR and VeeT, shall be isolated from the module
case.
2.This pin is an open collector/drain output pin and shall be pulled up with 4.7-10k to Vcc_Host
on
the host board. Pull ups can be connected to multiple power supplies, however the host board
design
shall
ensure that no module pin has voltage exceeding module VccT/R + 0.5
V.
3.This pin is an open collector/drain input pin and shall be pulled up with 4.7-10k to VccT in
the module.
4. See 2-wire Electrical Specifications
.
5. This pin shall be pulled up with 4.7-10k to Vcc_Host on the host
board.
Pin Description
Tx_Fault: Tx_Fault is an output pin to indicate a fault condition of a laser.This pin is connected
to ground in the module.
Tx_Disable: Tx_Disable is an input pin to disable the transmitter output. This pin is pulled high in
the module with a 5.11kOhm resistor.
SDA/SCL: SDA and SCL are the data and clock pins for the I2C interaction with the
EEPROM. These pins are connected to the SDA and SCL pins of the EEPROM in
the module.
MOD_ABS: Mod_Abs is an output pin to indicate that a module is present in the port. This pin is
connected to ground in the module.
RS0/RS1: RS0 and RS1 are module rate select pins to determine the transmit data rate for
lasers.
Rx_LOS: Rx_LOS is an output pin to indicate if the signal amplitude is below the receiver
threshold. This pin is connected to ground in the module.
Ground: VeeT and VeeR are connected within the module and are used as a digital ground
for signal integrity. This digital ground does not connect to the module case or the
copper cable braid.
Power: VccT and VccR are connected within the module and are used to power the EEPROM.
Typical voltage is 3.3 Volts and each pin has a maximum current capacity of 500 mA.
Signal: The two high speed signal pairs, TD+/TD- and RD+/RD-, are 100 Ohm differential
impedance transmission lines with AC coupling on each RD trace.