Timing and Electrical
Parameter
Symbol
Min
Typical
Max
Unit
Tx Disable Negate Time
t_on
1
ms
Tx Disable Assert Time
t_off
10
µs
Time To Initialize, including Reset of Tx
Fault
t_init
300
ms
Tx Fault Assert Time
t_fault
100
µs
Tx Disable To Reset
t_reset
10
µs
LOS Assert Time
t_loss_on
100
µs
LOS De-assert Time
t_loss_off
100
µs
Serial ID Clock Rate
f_serial_clock
100
400
KHz
MOD_DEF (0:2)-High
V
H
2
Vcc
V
MOD_DEF (0:2)-Low
V
L
0.8
V
Diagnostics
Parameter
Range
Unit
Accuracy
Calibration
Temperature
0 to +70
°C
±3°C
Internal
-20 to +80
-40 to +85
Voltage
3.0 to 3.6
V
±3%
Internal
Bias Current
0 to 100
mA
±10%
Internal
TX Power
-6.5 to +2
dBm
±3dB
Internal
RX Power
-17 to +1
dBm
±3dB
Internal
Digital Diagnostic Memory Map
The transceivers provide serial ID memory contents and diagnostic information about the
present operating conditions by the 2-wire serial interface (SCL, SDA).
The diagnostic information with internal calibration or external calibration all are implemented,
including received power monitoring, transmitted power monitoring, bias current monitoring,
supply voltage monitoring and temperature monitoring.