Supervision 2.3
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
© 2016 Bosch Security Systems, Inc. F.01U.301.248 | 04 | 2016.04
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
7 | Specifications
Dimensions 1.42 in x 1.42 in x 1.48 in (36 mm x 36 mm
x 37.6 mm)
Voltage (input) 12 VDC nominal
Current 18 mA in standby mode
35 mA in alarm mode
Operating
temperature
0°C to +50°C (+32°F to +122°F)
Relative
humidity
5% to 93% at +32°C (+90°F) non-
condensing
2-wire
smoke loop
thresholds
– Alarm: >13.5 mA
– Supervised + detectors: 5 mA – 10.5 mA
– Trouble: < 4 mA
2-wire smoke
loop wiring
50 Ω
0.65 mm (22 AWG) – 1500 ft (457 m)
1.02 mm (18 AWG) – 3900 ft (1188 m)
Compatibility B6512
B5512/B5512E v2.01 or higher
B4512/B4512E v2.01 or higher
B3512/B3512E v2.01 or higher
Manufacturer CTN Detector
identifier
Base Base
identifier
Detectors/
points
Bosch/
Radionics
D263/D263TH B N/A N/A 20
D263THS*/D263THC B N/A N/A 20
D285/D285TH A or B D287/D288 A 20
D286 A or B D287/D288 A 20
D603/D604/D605 A or B D287/D288 A 20
Detection
Systems
DS230/DS230F/DS233F A or B MB2W or MB2WL A 20
DS250/DS250TH A or B MB2W or MB2WL A 20
DS260 A or B MB2W or MB2WL A 20
DS282/DS282TH B N/A N/A 20
DS282THS/DS282THC B N/A N/A 20
Bosch F220-P/F220-PTH/F220-PTHC A F220-B6 A 20
F220-135/F220-135F/F220-190F A F220-B6 A 20
ESL/UTC 429C S10A N/A N/A 20
429CRT S11A N/A N/A 20
429CST* S11A N/A N/A 20
429CT S10A N/A N/A 20
511C S10A N/A N/A 20
711U/711UT S10A 701 E, 701 U, 702E, 702U S00 20
713-5U S10A 701 E, 701 U, 702E, 702U S00 20
721 UT S10A 702E, 702U S00 20
731 U S11A 702E, 702U, 702RE, 702RU S00 20
System Sensor 2W-B, 2WT-B A N/A N/A 20
2WTA-B A N/A N/A 20
5151 A B110LP, B110RLP, B401 A 20
* Compatible with the D132A Smoke Detector Reversing Relay Module.
4 | Compatible detectors
Use Remote Programming Software (RPS) to program the control panel to use the module and connected points.
For programming parameter descriptions, options, and defaults refer to RPS Help or the Program Entry Guide for your control panel.
After module installation and any control panel programming, perform a complete system test. A complete system test includes testing
the control panel, all devices, and communication paths for proper operation.
5 | Configuration and test
6 | Certifications
Region
US UL 365 - Police Station Connected Burglar Alarm
Units and Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and System
UL 985 - Household Fire Warning System Units
UL 1076 - Proprietary Burglar Alarm Units and
Systems
UL 1023 - Household Burglar-Alarm System Units
UL 1610 - Central-Station Burglar-Alarm Units
FCC Part 15 Class B
Canada CAN/ULC-S304 Central and Monitoring Station
Burglar Alarm Units
CAN/ULC S545 Residential Fire Warning System
Control Units
ULC/ORD-C1023 Household Burglar Alarm
System Units
CAN/ULC-S303 Local Burglar Alarm Units and
Systems
ULC/ORD-C1076 Proprietary Burglar Alarm
Units and Systems
en Installation Guide
2-wire Powered Loop Module
B201